Neurophysiology Tech Spec (NR)
Capital Health
- Pennington, New Jersey, United States
- Pennington, New Jersey, United States
About
Capital Health recognizes that attracting the best talent is key to our strategy and success as an organization. As a result, we aim for flexibility in structuring competitive compensation offers to ensure we can attract the best candidates.
The listed pay range or pay rate reflects compensation for a full-time equivalent (1.0 FTE) position. Actual compensation may differ depending on assigned hours and position status (e.g., part-time).
Pay Range:
$28.70 - $37.32
Scheduled Weekly Hours:
40
Position Overview
* Verifies identity of the patient using appropriate identifiers and verifies physician order for procedure. Measures the patient's head and attaches electrodes in accordance with the 10/20 international electrode placement system as evidenced by manager observations. Tests functional integrity of electrodes and assures acceptable electrode impedances.
* Obtains a complete and relevant patient history to include medications as evidenced by departmental documentation tools. Observes all patient safety measures, assuring side-rails on stretchers are upright and locked, except when transferring the patient, all wheelchair and stretcher wheels are locked and patients are under direct supervision by staff at all times as evidenced by manager observation and safety protocols.
* Removes all electrolyte/gel/collodian and cleans patient's scalp safely and thoroughly at the end of the testing. Logs and submits charges for all studies immediately upon completion in accordance with department policy and procedure. Utilizes appropriate infection control measures to ensure thorough cleansing of electrodes and other recording accessories as evidenced by equipment inspection.
* Prepares and provides an accurate technical report for the interpreting physician on all studies completed. Performs bio-calibration before and after each EEG study and records all montages in accordance with department policy and procedure as evidenced by the recordings. Performs applicable activation procedures and additional or special investigative montages as directed and/or in accordance with department policy and procedure.
* Transfers all studies upon completion via the network connection from the collection units (EEG, Ambulatory Reader) to the reader station and verifies
Languages
- English
Notice for Users
This job comes from a TieTalent partner platform. Click "Apply Now" to submit your application directly on their site.